| Ambient Temperature: | +25°C |
| Detector Operating Temperature | See model types below |
| Typical Cooler Power @/or near Max. Cooling: | 1.8 volts @1.2 amps |
|
Standard Specifications - Electrical All detector specifications are at a bias voltage of 50 V/mm distance between electrodes applied across the detector and with a one megohm load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C. |
||||
| Minimum | Typical | Maximum | Units | |
| Wavelength of Max. Response | 2.6 | 2.7 | µm | |
| D*(500K, 650 Hz, 1Hz) | 2.2 x 109 | 3.3 x 109 | cm Hz1/2 w-1 | |
| D*( lpk, 650 Hz, 1 Hz) | 2.0 x 1011 | 3.0 x 1011 | cm Hz1/2 w-1 | |
| Element Resistance (Dark) | 3.0 | 6.0 | 20.0 | Megohms/ |
| Time Constant (not measured) | 1750 | 3500 | µsec | |
| Rated Element Temperature | +65 | °C | ||
| DT@/or near Max. Cooling | 70 | 75 | °C | |
For square or rectangular element sizes and/or packages not listed, please contact our application engineers, phone (707) 545-4181, or fax (707) 545-5113.
When using the table below, remove parenthesis and insert appropriate designation for package type in this space. 6 for TO-66 and 8 for TO-8.
| Model Number |
Element Size (mm) |
Responsivity
(lpk, 650) vw-1 |
Operating Temp |
Standard Package Options |
|
| Minimum | Typical | ||||
| AT2S-1( ) | 1 x 1 | 1.4 x 106 | 2.1 x 106 | -50ºC | TO-66, TO-8 |
| AT2S-2( ) | 2 x 2 | 7.0 x 105 | 1.1 x 106 | -50ºC | TO-66, TO-8 |
| AT2S-3( ) | 3 x 3 | 4.3 x 105 | 6.5 x 105 | -45ºC | TO-66, TO-8 |
| AT2S-4( ) | 4 x 4 | 3.3 x 105 | 5.0 x 105 | -40ºC | TO-66, TO-8 |
| AT2S-5( )* | 5 x 5 | 2.7 x 105 | 4.0 x 105 | -35ºC | TO-66, TO-8 |
| AT2S-6( )* | 6 x 6 | 2.4 x 105 | 3.6 x 105 | -25ºC | TO-66, TO-8 |
| * Minimum D*(lpk, 650, 1) >1.0x1011 cm Hz1/2 w-1 | |||||